Supply voltage X9: 3 × 230–480 V AC (±10 %), 50–60 Hz
-
Maximum continuous mains current (S1): 36 A eff. (at 400 V supply and power factor 0.65)
-
DC bus voltage at X9C (400 V AC supply): 560–570 V DC
-
24 V DC supply X9B: 24 V DC (±20 %, max. 1 A) plus current for any existing holding brake and I/Os
-
Rated output power: 24 kVA (16 kW)
-
Maximum output power (2 s): 60 kVA
-
Rated output current: 40 A eff.
-
Maximum output current (2 s): 100 A eff.
-
Derating of rated output current at fPWM = 16 kHz: 28 A eff.
-
Derating of max. output current for 2 s at fPWM = 16 kHz: 70 A eff.
-
PWM frequency (fPWM): 4–16 kHz (software adjustable)
-
Brake resistor: 15 Ω
-
Continuous / pulse power: 160 W / 36 kW
-
External brake resistor: 15 Ω ≤ R_ext ≤ 50 Ω
-
Continuous power: ≤ 10 kW
-
Device dimensions with mounting plate and screw heads (H × W × D): 390 × 165 × 263 mm (without connector)
-
Device dimensions (H × W × D): 351 × 162.5 × 256.5 mm
-
Weight: approx. 13.5 kg
-
Pollution degree: 2
-
Interfaces: USB 2.0, Ethernet, RS232 [X5], CAN Bus [X4], PROFIBUS-DP, EtherCAT, or PROFINET
-
Encoder evaluation: Universal encoder interface for motors with resolver, analog and digital incremental encoders with/without commutation signals, SinCos encoders (single/multiturn) with HIPERFACE®, HIPERFACE DSL®, high-resolution Heidenhain encoders, absolute encoders with EnDat 2.1 & 2.2
Available options:
-
With plugged FSM 2.0 FBA (Fieldbus Activation Module)
-
With plugged FSM 2.0 STO module (Safety Torque Off)